You simply mount a small plastic clip to every other joist.
Nm wire run through residential attics.
Fold the ground wires neatly into the back of the box photo 11.
In most cases the nm cable must closely follow the building surface or another means of support for the cable must be provided.
Also if they re run in an attic space above the insulation then they would also be adjusted for the attic ambient temperature.
Normally the cables carry 10 12 or 14 gauge conducting wires for individual house circuits.
Section 333 12 requires where run across the top of floor joists meaning the attic floor joists the cable shall be protected by substantial guard strips that are at least as high as the cable this is a performance requirement because you are not told how to do it just that you must do it.
It could be installed exposed in a residential garage or in an attic or basement.
There should be no excess wire or ends left in the attic.
If a lot of wires are already hanging from the bottom of the floor joists you can run the wires through raceways that fasten to the bottom of the joists.
Push the long wire through the hole in the top of the special green wire connector and connect the remaining wires to it by twisting the connector clockwise until it s tight.
Many basements attics and storage areas do not have drywall applied so the trusses joists or framing members are left exposed.
Nm cable is simply a bundle of individual conducting wires wrapped in a plastic vinyl outer sheathing.
Nm cable also commonly known by the common trade name romex is the most common form of electrical wire.
Snip all the white neutral wires to the same length 6 in.
However if a single gang device box without.
Any nm cables bundled together for more than 24 will require an ampacity adjustment.
After you窶况e run the wires through the clips you snap a plastic cover over the entire assembly.
Nec 336 18 and 370 17 type nm nonmetallic cable shall be secured at intervals not exceeding 4 1 2 feet and within 12 inches of each box.